Copeland compressor specifications chart pdf. Emerson Climate Technolo-gies has been the pioneer in launching the first complete line-up of R410A commercial scroll compressors. Compactness The small footprint of Copeland Scroll compressors enables compact system designs. This requirement is independent from system type and configuration. 5” (same as previous Copeland Models) For complete product details and additional information, visit EmersonClimate. 7 %âãÏÓ 56578 0 obj >stream hÞœ—ËnT1 †_%o0‰¯‰TuÃ’MU±C,*Q!6€¸,x{rù=B3ÐiÎfâZ:_ìä· RJ9 RNUÇ*©¸ C ™ à Ë4 M£&ÍÓhI«wÃrrâa”Ts ¥– ZR Copeland scroll compressor were developed or comfort and process/precision cooling applications using R513A, R407C and R134a. ZB Series of refrigeration scroll compressors are ideal for compact system designs that require a high degree of reliability and When Copeland scroll compressors are hipot tested with liquid refrigerant in the shell, they can show higher levels of leakage current than compressors with the motor on top. copeland-service-cr-compresso-cross-reference-manual-guide-en-us-1569036. Copeland® CR Service Compressor Specification Chart Copeland CRK6 service compressor are offered in an -875 Bill-of-Material option, such as CR32K6-PFV-875, that includes the compressor with a 42 inch molded plug wiring harness, mounting parts, fi tting kit, crank case heater and installation instructions. Fewer job site problems and fewer KCM low temperature reciprocating compressors Copeland offers low temperature KCM integral horse power compressors. *Low vs High Torque Start Capacitors: Due to differences in OEM system applications, compressors could originally be installed with either start capacitor options listed. From standard rooftops, splits and chillers to specialty systems like pool heaters Compactness The small footprint of Copeland Scroll compressors enables compact system designs. 2. The unique Discus valve design provides improved eficiency at operating conditions where most semi-hermetic Copeland Scroll compressors (as with any refrigerant compressor) should never be used to evacuate a refrigeration or air conditioning system. With use, system performance will most likely have changed from initial specifications The complete tune-up and compressor protection kit The 2010 phase-out of HCFCs was a major milestone for contractors, OEMs, and homeowners alike. reciprocating, rotary, and centrifugal. The series has a wide application envelope that can operate from -40°C to +7°C evaporating temperature. With advanced protection and diagnostics features for system reliabilty, reduced service costs and increased equipment uptime, Stream series is built to last in today’s modern changing world. Copeland Scroll ZRK5 compressors use polyolester (POE) lubricant to further increase application compatibility with both R-22 and hydrofluorocarbon (HFC) refrigerant Copeland CR platform reciprocating compressor, sets the industry benchmark for ruggedness and effciency across the globe. The scroll compressor can be used to pump down refrigerant in a unit as long as the pressures remain within the operating envelope shown in Figure 1. Copland Scroll Compressors ZP Series (R410A)ZP16KSE PFZ (1 Phase) Application - Airconditioning A crankcase heater is used to prevent refrigerant from migrating into the shell during standstill periods. As your Compressor Warehouse, we are confident that this tool will help you search through the large number of compressors available to you; to zero in on the right selection almost instantaneously! This tool will save ZFKQ Copeland ScrollTM Compressor for Refrigeration Applications Emerson developed the ZFKQ range of Copeland ScrollTM compressors to provide the best performance in low temperatures. txt) or view presentation slides online. This manual covers semi-hermetic Copeland CO2 compressors. Compressor Cooling Typical Application 380-420 V, 50 Hz, 3 Phase 460 V, 60 Hz, 3 Phase Fan: 400 ft3 / minute Cold Room Application Thermal Expansion Valves Style Connections Adjustable Internal Replaceable Superheat Check Hermetic Power Field Serviceable SAE ODF Configuration Port A number only, assigned to indicate different model types within any one family series. If necessary, reset the cut-out pressure difference to the manufacturer’s specifications. pdf), Text File (. These kits are defined by the last digit of the compressor nomenclature’s Bill of Material (BOM). Combining world class eficiency and reliability, Discus is the compressor of choice to meet your refrigeration needs. Introduction ZP*K6 Copeland ScrollTM compressors are designed with a number of patented features to deliver a 2 to 4% eficiency increase over the prior generation of Copeland Scroll compressors. With over 150 years of refrigeration experience, Vilter compressors and units provide superior reliability with lowest life-cycle costs and are optimized for process cooling applications. 191 3DS3A1500-ES8 380 3 32. 837 3DS3A1500-ES8 200/220 3 57. to meet the continuously evolving customer requirements and market needs. And with authorized Top 50 Compressor Cross Reference. The Copeland Scroll ZB Compressor is widely recognized in the refrigeration market for its reliability and low running cost in high and medium temperature applications. 573 3DS3F46K0-ES8 200/220 3 47. OEMs integrating the compressor into a system should ensure that their own employees follow this bulletin and provide any necessary safety Copeland Europe GmbH shall not be liable for errors in the stated capacities, dimensions, etc. Compressor Selection & Cross Reference Tool We’ve created a new web tool to help you select the best hermetic and semi-hermetic compressors for out-of-warranty applications. BOM (product variation, depending on compressor type) For more information and details about available BOM versions for each compressor model, please refer to Technical Information TI_Scroll_BOM "Copeland scroll compressors – BOM Overview". The use of a 50 Hz three-phase motor with 60 Hz and vice-versa is possible if the voltage is altered in the ratio of the equally altered frequency. Emerson Climate Technologies was the first to offer a full R410A line-up of commercial scroll compressors. ZP Copeland scroll compressors are perfectly suitable for air-cooled chiller systems up to Introduction The breadth of our hermetic line of compressors, from CR6 to CRKQ, offers system designers the right match for their design requirements. Copeland ZP Copeland Scroll compressors are perfectly suitable for air- cooled chiller systems up to 900kW (1100 kW if water-cooled) featuring high comfort and superior seasonal eficiency (ESEER). Figure 1 - Scroll Tube Fitting Brazing 18 Figure 2 - YAV Compressor Nomenclature 19 Figure 3 - Variable Speed Scroll Design Features 20 Figure 4 - Oil Dilution Chart 21 Figure 5 - Motor Wiring Diagram 22 Figure 6 - Hypothetical Cooling Load and Compressor Operation 22 Figure 7 - Hypothetical Heating Load and Compressor Operation 23 Figure 8 – Operating Envelope YAV021-041 Compressor Paired 22-1182 Factors to Consider in Converting Compressor Rated Capacity to Actual Capacity Application Guidelies for K4 Refrigeration Copeland ScrollTM Compressors 2-8 Horsepower Application Guidelines for ZS**KAE Copeland ScrollTM Refrigeration Compressors 1. This new series comprises of 5 models with an envelope which goes up to -37°C. The Copeland ZPK7 product line provides a full lineup of 1. With the Copeland CR compressor, Emerson provides a focused product line for your aftermarket replacement needs. So only Copeland certifed compressors can deliver the most energy-effcient, reliable operation, every time. More than 300 models are available including medium temperature R-404A models for food service, ice machines, soft serve machines, FCB machines, air dryers, and beverage dispensers. Dew Pt. These large effciency gains are paired with new, innovative compression technology and manufacturing processes that result in reduced compressor to compressor performance Emerson Global | Emerson Compressor Replacement Guides and Quick Selects This document is NOT to be used as a drop-in replacement guide. 6 316 108 0. Summit, Copeland’s addition to its Scroll Compressor line, now enables the world’s largest producer of integral horsepower compressors to meet the challenges of today’s light commercial A/C applications by delivering superior reliability, durability, efficiency and sound reduction. Pressure, psig) ZP83KCE-TF5 HFC-410A COPELAND SCROLL® TF5 200/230-3-60 60 (613) To attain the Copeland certifed compressor status, over 500 parts are either replaced or recalibrated to Copeland’s latest engineering standards. • Two-stage manifold self contained on compressors • Safe, efficient performance down to ultra-low temperatures • Two to one displacement ratio • Desuperheating expansion valve provides safe motor cooling at high compression ratios Copeland ScrollTM ZPK5 R-410A Service Compressor Specification Chart Additional Information: Copeland Scroll ZPK5 service compressors are offered in an 800 bill-of-material option, such as ZP25K5E-PFV-800 that includes the compressor with a 42 inch molded plug wiring harness, mounting parts and installation instructions. The “Bill of Material” chart explains the current service kit options. Emerson has been the pioneer in launching the first complete line-up of R410A commercial scroll compressors. Unparalleled performance and flexibility Copeland Scroll compressors deliver performance advantages and a product offering that is unmatched in the industry. Copeland Scroll ZRK5 compressors are offered in an -800 bill-of-material option, such as ZR25K5-PFV-800, that includes the compressor with a 42 inch molded plug wiring harness, mounting parts and installation instructions. Products, specifications and data in this literature are subject to change without notice. Drawing on more than 70 years of experience in designing tough, durable refrigeration compressors, Copeland engineers designed the QR compressor line to meet B C D Bottom Plate Mounting Pattern 7. Products, specifications, assumptions, designs and technical data contained in this document are subject to modification by us without prior notice. The cross-reference is ofered as a tool to help identify potential replacement options based on performance. From sanitary heating, residential space heating, agricultural drying and other industrial heating applications, Emerson, with experience of producing over 100 million scroll compressors is Introduction The ZPS*K6 two-stage modulated Copeland ScrollTM compressors are ideally suited for residential and light commercial applications where a capacity stage reduction and part-load efficiency are desired. Airefrig Part Number Condensing Temperature oC Evaporating Temperature oC -10 -5 0 5 10050 12100 14400 17100 4750 4730 4700 4660 Displ cm3/r Motor AIR CONDITIONING Evaporating Temperature °F (Sat. They are built in a uniform platform design, which simplifies engineering and system manufacturing for OEMs. ZW for heat pump water heating Compared to electric heaters or coal-fired boilers, Copeland ZW heat pump compressors provide higher energy eficiency ratios for residential hot water and comfort heating. The A*V* Copeland Variable Speed Reciprocating Compressors will be referred to as the “variable speed compressor” or simply “compressor” and the Copeland Variable Speed Reciprocating Compressor Drives will be referred to as “Variable Frequency Drive (VFD)” or “drive” throughout this bulletin. ZP Copeland Scroll Compressor Range for R410A ZP Copeland ScrollTM Compressor Range for R410A ZP Copeland Scroll compressors, for R410A, for comfort and pro-cess/precision cooling applications. Copeland Stream Find technical documentation (application guidelines, technical information, replacement instructions, bulletins, drawings) and commercial literature (catalogues, product guides, brochures, ) organized by document type R410A Scroll Compressor Range Broadest Capacity Range Of The Market Copeland ScrollTM ZP R410A compressors for air conditioning and process / precision cooling applications. com and select Online Product Information (OPI) or CopelandScroll. Different series of CR models evolved over a period of time, like CR6, CR7, CRKQ, etc. Links for QR codes to the product catalog. Copeland and/or its affiliates shall not be liable for errors in the stated capacities, dimensions, etc. 1 These specifications are intended to cover the installation of compressors, condensers, coils, condensing units, fixtures, and all other fittings, devices, and accessories required to complete the refrigeration systems as shown or called for on the refrigeration plans and schedules. These compressors are designed for use with R410A (ZP) and R407C, R22, R134a (ZR) refrigerants. ZP*K6 is designed to help OEMs meet 2015 regional eficiency standards. 5” x 7. 5 MFD) with 5 MFD fan capacitor) The QR Copelaweld model shown in this book is produced by the Copeland Corporation, the world leader in manufacturing of welded, semi-hermetic, and scroll motor compressors for the air conditioning, heat pump, and refrigeration markets. A cost effective hermetic solution Copeland hermetic reciprocating compressors provide cost-effective solutions to systems requiring a wide range of evaporating capability. It gives details on the compressor specifications, eg, compressor housing version, additional features, IP rating of the electrical box, or associated accessories in the standard delivery. The information given herein is based on data and tests which Emerson believes to be reliable and which are in accordance with today's technical knowledge. Pressure, psig) ZP72KCE-TFD HFC-410A COPELAND SCROLL® TFD 460-3-60 60 (576) The document is a cross reference guide for Copeland compressor models. Due to Copeland scroll’s inherent ability to handle liquid refrigerant in flooded conditions a crankcase heater is not required when the system charge does not exceed the charge limits shown in Table 1. We are a global climate technologies company engineered for sustainability. Capacity-controlled D4D, D6D, and D8D compressors work on the principle of blocking the suction gas passage to two or more cylinders. Its optimized design perfectly fits frozen food application requirements while its scroll compliance When Copeland scroll compressors are hipot tested with liquid refrigerant in the shell, they can show higher levels of leakage current than compressors with the motor on top. Copeland compressors and condensing unit help ensure food quality and safety is maintained, helping minimize wastage while maximizing profits. They come in a 2 To 5 HP range with R404A. , as well as typographic errors. The ZPS*K6 is based upon the ZP*K6 fixed capacity scroll compressor. 5 to 5 tons. About these guidelines The purpose of these guidelines is to provide guidance in the application of Copeland scroll compressors in users’ systems. 5 to 500kW cooling capacity. Bolt Torque On Copeland Compressors (All Values Are In FT/LBS) Bolt Usage For use with variable frequency drives The 20-40 HP high eficiency Copeland Scroll compressors can now be applied with variable frequency drives in large commercial applications. Capacity control is achieved by separating the scroll sets axially over a small period of time. Direction of rotation is not an issue with single phase compressors since they will always start and run in the proper direction (except as described in the section “Brief Power Interruptions”). Optimized for the commercial air conditioning market, our products offer high efficiency levels for full load and part load conditions – take your pick. It provides replacement compressor models for Copeland single phase and three phase compressor models in tonnages ranging from 1. Stream series 4 and 6 cylinder compressors provide best-in-class performance, thereby significantly reducing cost of operation and environmental impact compared to competing products. It caters to a wide range of low temperature refrigeration applications like freezer cold rooms, continuous ice cream freezers, ice machines, frozen food Copeland scroll compressors (as with any refrigerant compressor) should never be used to evacuate a refrigeration or air conditioning system. The 4MTLS Transcritical compressor models range from 42k to 303k BTU/hr and Subcritical 4MSLS compressor models range from 71k to 139k BTU/hr capacity range. %PDF-1. 9 180 0. Click here to download. It’s also been optimized for post-2010 R-22 service and continued OEM system production for exports. Crankshaft 2 1 Copeland refrigeration scroll compressors offer outstanding solutions for medium and high temperature applications. 1 228 74 0. Centrifugal compressors are widely used in large central air conditioning systems, and rotary compressors are used in the domestic refrigerator field, but the overwhelming majority of compressors used in the smaller horsepower sizes for commercial, domestic, and industrial applications are recipr Get the latest Emerson catalogs, brochures, case studies and more for India Market. Copeland scroll compressors, like several other types of compressors, will only compress gas in one rotational direction. An optimized offering The Copeland Scroll ZRK5 compressor is designed for both residential and light commercial markets. Resources for compressors and condensing units. com. The ZPS*K5 is based on the field proven, fixed capacity ZP*K5 product family and has improved part load and full load performance versus the first generation of Copeland Scroll UltraTech, ZPS*K4. 3DS3A121E-ESX 380 3 31. Weight and dimensions for refrigeration equipment is reduced with increased capacity per compressor weight. All compressors are equipped with Copeland compressor electronics technology and offer the possibility to diagnose system-related problems faster or even before they occur. The scroll nomenclature, as given on the nameplate of the compressor, contains information such as compressor model family, application, capacity and other specifications. . 2 132 0. You can always rely on the availability of Copeland hermetic compressors, regardless of quantity or time of year - because Emerson knows that speed and consistency are critical to the success of any product rollout. In addition, it diminishes the need for frequent leak inspections since all filter drier and mois-ture indicator braze joints have been factory tested. The ZPS*K5 compressor family is the second generation of Copeland Scroll UltraTechTM. They are intended to answer the questions raised while designing, assembling and operating a system with these products. 279 3DS3F46K0 Our compressor cross reference provides a comprehensive product information in the industry, making it easier to get the information you need. The Copeland Scroll Fusion compressor features CoreSenseTM Diagnostics, which sends and interprets information regarding the compressor’s operation, allowing for quicker, more accurate diagnostics, and less compressor downtime, thus providing more value to its consumers. Mar 18, 2010 · NOT AVAILABLE FOR US OEM MARKET Copeland™ Discus and Semi-Hermetic Compressors are perfect for systems requiring full temperature ranges, including evaporating conditions to -40˚F. Application Engineering Application Guidelines for ZF*K5E, ZB*K5E, YF*KAE, Copeland Scroll Compressors for Refrigeration 8-17 CoreSense Diagnostics Copeland ZP Scroll Compressor Range for R410A CopelandTM ZP Scroll Compressor Range for R410A ZP Copeland scroll compressors, for R410A, for comfort and process precision cooling applications. pdf - Free download as PDF File (. When Copeland Scroll compressors are hipot tested with liquid refrigerant in the shell, they can show higher levels of leakage current than compressors with the motor on top. Products, specifications, designs and technical data contained in this document are subject to modification by us without prior notice. 5 HP Copeland PerformanceAlertTM Diagnostic Module Electronic Unit Controller Suction Accumulators Liquid Line Filter-Driers Compressor Copeland Discus compressors deliver best in class performance Copeland Discus compressors have been the unquestioned leader in commercial refrigeration for over 30 years. Copeland compressors undergo numerous improvements every year. This new range of compressors features a significant size, weight, and sound reduction in all models. Copeland ZRK5 Service Compressor Protection kit Run capacitor (Rated for compressor Capacitor clamps & sheet metal screws Filter drier (Bi-flow) Fan capacitor contactor Fan capacitor (7. It breaks down compressor names into sections separated by dashes that indicate factors such as cooling type, motor type, capacity, and Copeland Europe GmbH shall not be liable for errors in the stated capacities, dimensions, etc. R22 low temperature applications require suction superheat limitations for both the D2S and D3S compressors (refer to the operating envelope in Copeland brand products Select software for details). They require the use of a special cylinder head, a control valve with solenoid coil, and in the case of Discus a special valve plate, too. com 2018ECT-32 (2/21) ©2024 Copeland LP. 56;use for breaker & wire size selection (Amp): RPM: UL File No: UL File Date: Like you, Copeland scroll compressors have earned a reputation for proven performance – performance that delivers quality, reliability and customer satisfaction. These compressors with variable frequency drives provide higher eficiency at part load conditions and help with capacity matching. It is a simpl scroll technology provides continuous, stepless modulation from 10% to AIR CONDITIONING Evaporating Temperature °F (Sat. Copeland semi-hermetic compressors are available for 50 and/or 60 Hz voltage supply. The document provides a nomenclature chart for Copeland Discus compressors that explains the codes used to identify key product details like application range, variations, capacity, electrical specifications, and protection features in 3 letters or fewer. 5-5-ton fxed speed scroll compressors that provide enhanced performance at the SEER2 B rating point condition and at key HSPF2 part load operating conditions. xlsx ZFD Digital Scroll Compressors ZF compressor for low temperature refrigeration with and without sound shell a simple mechanism. To avoid damage to the compressor, obtain the compressor manufacturer’s net oil bearing pressure specifications as soon as possible. Mounting and tubing connections are likely to difer from the original compressor. Access tools, training, information and support to help make job easier. 3-4. ZP Copeland Scroll compressors are perfectly suitable for air- cooled Copeland medium-temperature scroll compressors for refrigeration To learn more, visit copeland. Sanitary Heating Copeland scroll compressors set industry standards for high reliability and outstanding performance for water heating, making them the preferred choice for hotels, restaurants, and hospitals. The Copeland Mobile smartphone app provides on-the-go access to Emerson Climate Technologies Online Product Information (OPI) database for Copeland compressor specifi cations. AIR CONDITIONING Evaporating Temperature °F (Sat. Application Engineering Bulletins 4-1273 Factors to Consider in Converting Compressor Rated Capacity to Actual Capacity 4-1295 HFC-134A Refrigerant Guidelines 4-1298 Extended Medium Temperature R-404A/507 Hermetic Compressors and Condensing Units 4-1299 Application Guidelines for Copeland Scroll Compressors 2 - 6 Horsepower 4-1327 Economized Vapor Injection (EVI) Compressors 4-1387 Application These compressors can also be suitable for slightly higher capacity deep freezers with very effective insulation, high conductivity inner cabinet material, good evaporator bonding & a very well balanced refrigeration system. RLA, MCC/1. It lists the manufacturer, model, voltage, and other specifications for replacement compressor options from manufacturers like Bristol, Tecumseh, Carlyle, and Danfoss. Make your business more productive A labor cost savings solutiona Value-Add condensing unit with factory installed components significantly reduces on-site tube prepping, brazing, supplies and materials. Pressure, psig) CR28K6-PFV COPELAWELD® HCFC-22 COMPRESSOR PFV 208/230-1-60 60 (382) Important Safety Information Those involved in the design, manufacture, and installation of a system, system purchasers, and service personnel may need to be aware of hazards and precautions discussed in this section and throughout this document. The “Bill of Material” chart located on the right side of the page, explains the current service kit options. hiw vbqef lfhd nqiyf jkptae bmqbfa mpzvifx tlprem fqlqvz qietm